Concrete Pipe Weight Calculator

Pick a pipe size (12 to 108 inches) and wall type A, B or C to get the ACPA approximate weight per foot and the total for your length, or enter any ID and wall thickness to calculate the barrel weight in lb, kg, lb/ft and kg/m.

Reinforced concrete pipe (ASTM C76, tongue-and-groove) weighs about 93 lb/ft for 12-inch Wall B, 264 lb/ft for 24-inch, 524 lb/ft for 36-inch and 867 lb/ft for 48-inch Wall B, per the American Concrete Pipe Association table at 150 lb/ft³ concrete.

Use the Concrete Pipe Weight Calculator

RCP weight by size and wall (ASTM C76)

Approximate weights per the American Concrete Pipe Association table, tongue-and-groove joint, 150 lb/ft³ concrete.

Weight per foot
—
—
Wall / OD
—
—
One 8-ft joint
—
typical laying length
Total for run
—
—

Pipe Specification

Standard for RCP: specify hydraulic inner diameter and wall thickness.

Switching units automatically converts entered numbers.

Estimated Weight Barrel Only

Enter pipe dimensions and press Calculate Pipe Weight.

Geometric Relationships & Engineering Bounds

  • Diameter relation: OD = ID + 2 × Wall Thickness. Annular area = π × (ID + Wall) × Wall = (π/4) × (OD² − ID²).
  • Linear weight conversion: 1 kg/m = 2.204622 lb / 3.28084 ft ≈ 0.671969 lb/ft.
  • Density standard: ACPA references 150 lb/ft³ (≈ 2,403 kg/m³) for standard reinforced concrete pipe (RCP). Actual product weight varies with the concrete mix and reinforcement; use manufacturer data for final decisions.
  • Joint exclusion notice: Calculations reflect nominal circular barrel only. Bell, socket, spigot, tongue-and-groove joint profiles, gaskets, and embedded lifting anchors are excluded. Certified manufacturer submittals govern lifting, crane rigging, and transportation loads.

Concrete pipe weight chart — ASTM C76 Wall A, B and C

Minimum wall thickness and approximate weight in pounds per foot for round reinforced concrete pipe with tongue-and-groove joints, from the American Concrete Pipe Association Concrete Pipe Design Manual (Illustration 5.2), based on concrete at 150 lb/ft³. Multiply lb/ft by 1.488 for kg/m.

Reinforced concrete pipe wall thickness and weight per foot by inside diameter and wall type
ID (in)Wall AWall BWall C
Walllb/ftWalllb/ftWalllb/ft
121¾ in792 in93——
151⅞ in1032¼ in127——
182 in1312½ in168——
212¼ in1712¾ in214——
242½ in2173 in2643¾ in366
272⅝ in2553¼ in3224 in420
302¾ in2953½ in3844¼ in476
332⅞ in3363¾ in4514½ in552
363 in3834 in5244¾ in654
423½ in5204½ in6865¼ in811
484 in6835 in8675¾ in1,011
544½ in8645½ in1,0686¼ in1,208
605 in1,0646 in1,2956¾ in1,473
665½ in1,2876½ in1,5427¼ in1,735
726 in1,5327 in1,8117¾ in2,015
786½ in1,7977½ in2,1008¼ in2,410
847 in2,0858 in2,4098¾ in2,660
907½ in2,3958½ in2,7409¼ in3,020
968 in2,7109 in3,0909¾ in3,355
1028½ in3,0789½ in3,48010¼ in3,760
1089 in3,44610 in3,86510¾ in4,160

Large sizes (one wall listed)

Large reinforced concrete pipe sizes with wall thickness and weight per foot
ID (in)Walllb/ft8-ft joint (lb)
1149½ in3,84030,720
12010 in4,26334,104
12610½ in4,69037,520
13211 in5,14841,184
13811½ in5,62745,016
14412 in6,12649,008

Wall A ≈ diameter in feet, in inches; Wall B = A + 1 in; Wall C = A + 1¾ in (small sizes use set minimums). Bell-and-spigot pipe, heavier concrete and thicker production walls weigh more; use the manufacturer submittal for lifting and haul limits.

Copied to clipboard

Quick answer

Reinforced concrete pipe (ASTM C76, tongue-and-groove) weighs about 93 lb/ft for 12-inch Wall B, 264 lb/ft for 24-inch, 524 lb/ft for 36-inch and 867 lb/ft for 48-inch Wall B, per the American Concrete Pipe Association table at 150 lb/ft³ concrete. Weight per foot = 150 × π/4 × (OD² − ID²) ÷ 144 with diameters in inches, where OD = ID + 2 × wall. An 8-ft joint of 24-inch Wall B pipe is about 2,110 lb.

Examples

Inside diameterWall AWall BWall C
12 in79 lb/ft (1¾ in wall)93 lb/ft (2 in)—
18 in131 lb/ft (2 in)168 lb/ft (2½ in)—
24 in217 lb/ft (2½ in)264 lb/ft (3 in)366 lb/ft (3¾ in)
36 in383 lb/ft (3 in)524 lb/ft (4 in)654 lb/ft (4¾ in)
48 in683 lb/ft (4 in)867 lb/ft (5 in)1,011 lb/ft (5¾ in)
72 in1,532 lb/ft (6 in)1,811 lb/ft (7 in)2,015 lb/ft (7¾ in)

Pick a size and wall type and enter your length to get the total weight, or type any ID and wall thickness.

Summary

Round reinforced concrete pipe is sized by inside diameter and wall type. ASTM C76 gives three wall thicknesses for each size: Wall A (about the diameter in feet, in inches), Wall B (A + 1 inch) and Wall C (A + 1¾ inches). This page carries the American Concrete Pipe Association table of approximate weights per foot for tongue-and-groove pipe from 12 to 108 inches, based on 150 lb/ft³ concrete, plus the ACPA large sizes to 144 inches. Pick a size and wall to get the weight per foot, per 8-ft joint and for your run length, or enter any inside diameter and wall thickness (or OD) to calculate the barrel weight from geometry. Manufacturer weights vary with joint shape, concrete density and wall thickness, so use the supplier submittal for lifting and haul plans.

How it works

  1. Pick the inside diameter and the ASTM C76 wall type (A, B or C) in the size picker.
  2. Enter the run length in feet to get the total weight in pounds, tons and kilograms, plus the weight of one 8-ft joint.
  3. Click "Use in calculator" to load that ID and wall into the barrel calculator, or type any ID and wall thickness (or OD) yourself.
  4. Choose a concrete density (reinforced 2,400 kg/m³ ≈ 150 lb/ft³ by default) and press Calculate Pipe Weight.
  5. The calculator returns annular area π/4 × (OD² − ID²), volume, total weight and weight per foot and per metre.

Use cases

  • Checking the weight per foot of 12- to 108-inch RCP before ordering trucks or a crane.
  • Totaling the weight of a storm sewer or culvert run for a bid or a haul plan.
  • Comparing Wall A, B and C weights for the same diameter.
  • Estimating barrel weight for a non-standard wall thickness or metric pipe.
  • Converting pipe weights between lb/ft and kg/m.

Frequently Asked Questions

Last updated: 2026-10-10 · Reviewed by Nham Vu